Dimensions and Rack Mounting

The TSXDSY64T2K discrete output module fits directly into Modicon TSX Premium racks. Its housing measures 160 mm × 105 mm × 40 mm and weighs about 0.45 kg. Therefore, the unit occupies one standard rack slot without extra hardware. A front panel carries a removable terminal block plus status LEDs for each channel group. The rear edge connector mates with the rack bus for power and addressing.

Output Channels and Electrical Ratings

The TSXDSY64T2K provides 64 transistor outputs arranged in four isolated groups. Each channel switches 0.5 A at 24 V DC for solenoid and lamp loads. The outputs respond within 1.5 ms, so they suit fast machine sequencing tasks. Moreover, short-circuit protection guards every group against wiring faults. The module draws 250 mA at 5 V DC from the backplane supply.

ParameterValue
Dimensions (W × H × D)160 × 105 × 40 mm
Weight0.45 kg
Output Channels64 transistor outputs
Output Groups4 isolated groups
Channel Rating0.5 A at 24 V DC
Response Time1.5 ms
ProtectionShort-circuit per group
Supply Draw250 mA at 5 V DC

Component Count and Energy Storage

The TSXDSY64T2K carries 70 discrete components on its output driver board. For energy storage, three 100 µF capacitors filter the logic supply rail across the driver sections. These capacitors absorb switching transients and protect the output transistors. The module needs no battery, so routine upkeep stays minimal. Operating temperature covers 0 °C to +60 °C in standard control cabinets.

Details

Weight0.15 kg
Dimensions110 × 72 × 38 mm