The GE IS200VTURH1B IS200VTURH1BAB PCB manages turbine voltage regulation tasks within Mark VI racks. This board monitors incoming power signals and provides stable reference voltages. You will find this unit inside a standard Speedtronic control enclosure. It works alongside other Mark VI boards for complete turbine protection.
Technical Specifications
The table below lists accurate parameters for this printed circuit board.
| Parameter | Specification |
|---|---|
| Full Product Model | GE IS200VTURH1B IS200VTURH1BAB |
| Category | PCB (Printed Circuit Board) |
| Width | 3.5 inches (88.9 mm) |
| Height | 9.5 inches (241.3 mm) |
| Weight | 0.58 kg (1.28 lbs) |
| Onboard Components | 1 voltage regulator, 6 capacitors, 12 resistors |
| Connector Interfaces | 2 backplane connectors (P1, P2) |
| Energy Storage | 3 electrolytic capacitors (220 µF each) |
| Operating Voltage | 5 V DC from backplane supply |
| Power Consumption | 12 W typical |
Physical Layout and Component Arrangement
The GE IS200VTURH1B IS200VTURH1BAB PCB uses a rigid epoxy substrate with a green solder mask. One primary voltage regulator sits at the center of this board. Six electrolytic capacitors surround the regulator for enhanced power filtering. Twelve surface-mount resistors control current flow across various circuits. Two backplane connectors anchor this PCB securely into the Mark VI rack.
Functional Features and Integration
This voltage regulation board stabilizes incoming DC power for downstream modules. It filters out electrical noise that could disrupt sensitive processor operations. The GE IS200VTURH1B IS200VTURH1BAB also provides overvoltage protection for connected components. Consequently, it plays a critical role in system reliability and uptime.
Installation and Safe Handling
Always power down the entire rack before inserting this PCB. Hold the GE IS200VTURH1B IS200VTURH1BAB firmly by its non-conductive edges. Push the board straight down until both backplane connectors lock into place. Then secure the front panel screw to prevent vibration-related loosening. After installation, verify voltage readings through the Mark VI diagnostic menu.
Details
| Weight | 0.1 kg |
|---|---|
| Dimensions | 25 × 108 × 127 mm |

Reviews