This dedicated protection board monitors critical turbine parameters for safe operation. The GE IS200VTURH1B IS200VTURH1BAA executes independent safety logic separate from the main controller. Sixteen analog input channels acquire speed, temperature, and vibration signals continuously. Consequently, the board can initiate an emergency trip without any processor intervention.
Technical Specifications of the Protection Board
The GE IS200VTURH1B IS200VTURH1BAA fits a standard VME 6U form factor seamlessly. Its height measures 233.4 mm, and its depth reaches 160 mm. The board weighs approximately 0.7 kg including all protection circuitry. A single front panel LED array shows trip status and channel health at a glance. The rear side uses a 64-pin DIN 41612 connector for backplane signals and power. This design stores minimal energy in small filtering capacitors only. Therefore, the board contains no batteries or large energy storage elements.
| Parameter | Specification |
|---|---|
| Full Model | GE IS200VTURH1B IS200VTURH1BAA |
| Category | Primary Turbine Protection Board |
| Dimensions (H x D) | 233.4 mm x 160 mm |
| Weight | Approximately 0.7 kg |
| Analog Inputs | 16 single-ended channels |
| Digital Outputs | 8 trip relay outputs |
| Trip Thresholds | Programmable per channel |
| Response Time | Less than 10 milliseconds |
| Rear Connector | 64-pin DIN 41612 |
| Energy Storage | Minimal (filtering only) |
| Supply Voltage | +5V DC at 1.0 A typical |
Functional Features and Safety Logic
The GE IS200VTURH1B IS200VTURH1BAA compares each input against independent high and low trip limits. You can configure voting logic using any combination of the sixteen channels. The onboard hardware implements all trip decisions without relying on software. This hardwired approach guarantees deterministic response times for critical protection. Each trip output uses a normally energized relay for fail-safe operation.
Installation and System Integration
You must install this protection board into a dedicated VME backplane slot. The GE IS200VTURH1B IS200VTURH1BAA communicates trip events to the main processor via the backplane. A front panel test button allows manual trip simulations during maintenance checks. The board also records the first trip cause for later fault analysis. Always verify wiring connections before applying power to the system.
Maintenance and Safety Benefits
Because the GE IS200VTURH1B IS200VTURH1BAA stores no battery-backed data, it requires no periodic battery replacement. Technicians can replace the board without losing trip history or configuration settings. The eight relay outputs remain in a safe state during board removal or installation. Consequently, turbine protection never compromises even during maintenance procedures.
Details
| Weight | 0.1 kg |
|---|---|
| Dimensions | 25 × 108 × 127 mm |

Reviews
There are no reviews yet.