This GE IS200TRPGH2B IS200TRPGH2BDE Primary Trip Terminal Board provides termination for critical turbine trip circuits. The board interfaces between protection relays and the emergency shutdown system. You will find this component in many GE Mark VI safety-critical applications. The IS200TRPGH2BDE variant includes a rugged conformal coating for harsh environments.
Technical Specifications
| Parameter | Specification |
|---|---|
| Full Model | GE IS200TRPGH2B IS200TRPGH2BDE Primary Trip Terminal Board |
| Category | Primary Trip Terminal Board |
| Trip Inputs | 8 Dedicated Trip Channels |
| Output Relays | 4 Safety Relay Outputs (Form C, 10A) |
| Input Voltage Range | 24V to 250V AC or DC |
| Response Time | Less than 5 milliseconds |
| Isolation | 4000 V RMS between Channels |
| Dimensions (H x W) | 240 mm x 180 mm |
| Weight | Approximately 1.25 kg |
| Connectors | 2 x 50-Pin Ribbon Headers, 1 x Terminal Block |
| Component Count | 112 Discrete Components |
| Energy Storage | None (Passive Board) |
Trip Circuit and Safety Features
The GE IS200TRPGH2B IS200TRPGH2BDE Primary Trip Terminal Board routes critical trip signals directly to the safety system. Each input channel includes surge suppression for reliable operation. The board provides force-guided relay contacts for fail-safe operation. Furthermore, it includes status feedback for each relay’s contact position. Consequently, the system can verify trip circuit integrity continuously.
Installation and Connection Steps
Mount this GE IS200TRPGH2B IS200TRPGH2BDE Primary Trip Terminal Board in the lower section of any Mark VI cabinet. First, secure the board using four M6 mounting bolts at the corners. After that, connect trip sensor wiring to the terminal block following the printed labels. Then, attach the two ribbon cables to the corresponding trip controller board. Finally, verify each channel’s continuity before applying power to the system.
Energy Discharge and Safety Notice
This GE IS200TRPGH2B IS200TRPGH2BDE Primary Trip Terminal Board stores no significant energy. Therefore, you can handle it immediately after power removal. However, field wiring may carry hazardous voltages from external protection relays. Always disconnect external power before touching any terminal.
Status Indication and Diagnostics
Eight green LEDs indicate the active state of each trip input channel. Four yellow LEDs show the position of each safety relay output. A red LED illuminates when any channel detects a wiring fault. These indicators help technicians troubleshoot trip circuit issues without special tools.
Details
| Weight | 0.1 kg |
|---|---|
| Dimensions | 25 × 108 × 127 mm |

Reviews
There are no reviews yet.