This gas turbine emergency trip board provides critical overspeed protection for GE Mark VIe systems. It monitors turbine speed and initiates a shutdown when exceeding safe limits. Therefore, it prevents catastrophic turbine damage during overspeed events.
Physical and Protection Specifications
The GE IS200TREGH1A IS200TREGH1AAA measures 26.0 cm in length and 18.5 cm in width. Moreover, its board weight equals approximately 0.68 kg for rack mounting. A single 64-pin male connector links this board to the VME backplane. Additionally, the board integrates three independent speed monitoring channels.
| Parameter | Specification |
|---|---|
| Brand | General Electric (GE) |
| Full Model | IS200TREGH1A IS200TREGH1AAA |
| Category | Gas Turbine Emergency Trip Board |
| Dimensions (L x W) | 26.0 cm x 18.5 cm (10.24″ x 7.28″) |
| Board Weight | 0.68 kg (1.50 lbs) |
| Primary Interface | 1 x 64-pin Male Connector |
| Speed Input Channels | 3 Independent Channels (Voting Logic) |
| Input Type | Magnetic Pickup or Proximity Sensor |
| Input Voltage Range | 0 to 30 Vrms (Sine Wave) |
| Input Frequency Range | 10 Hz to 20 kHz |
| Trip Speed Accuracy | ±0.1% of Full Scale |
| Trip Response Time | < 20 ms (Overspeed to Trip Output) |
| Trip Outputs | 2 Form C Relays (3A at 250 VAC) |
| Voting Logic | 2-out-of-3 (TMR Architecture) |
| Overspeed Setpoint | Programmable (0 to 110% of Rated Speed) |
| On-Board Components | 3 Frequency Converters + 3 Comparator ICs + 2 Relay Drivers + 6 Protection Diodes + 1 Watchdog Timer + 2 Optocouplers + 1 Voltage Regulator |
| Energy Storage | 3 x 220 µF Electrolytic Capacitors (35V) + 2 x 10 µF Tantalum (25V) |
| Operating Voltage | +5 VDC and +24 VDC from Backplane |
| Isolation Rating | 2500 Vrms (Inputs to Outputs) |
| Operating Temperature | -20°C to +65°C (-4°F to +149°F) |
| Status Indicators | 3 Green LEDs (Sensor OK) + 2 Yellow LEDs (Trip Active) + 1 Green LED (Power) + 1 Red LED (Fault) |
Triple Modular Redundant Speed Monitoring
The GE IS200TREGH1A IS200TREGH1AAA uses three independent speed channels for fault tolerance. Specifically, the 2-out-of-3 voting logic prevents spurious trips from single sensor failures. In addition, each channel operates independently with its own frequency converter and comparator. Moreover, the module continuously compares all three speed readings for consistency. Furthermore, the trip accuracy of ±0.1 percent ensures precise overspeed detection. Consequently, this board provides highly reliable emergency protection for gas turbines.
Trip Response and Output Relay Features
When any two channels detect overspeed, the board activates the trip output relays. For instance, the response time from overspeed detection to trip output stays below 20 milliseconds. In addition, two Form C relays provide redundant trip contacts for downstream safety circuits. Moreover, the relay contacts rated at 3 amps can directly shut down fuel valves. Furthermore, a watchdog timer monitors firmware execution and activates a hardware trip if needed. Thus, the GE IS200TREGH1A IS200TREGH1AAA ensures turbine shutdown even during processor faults.
Energy Storage and Trip Integrity
This emergency trip board stores energy using five onboard capacitors for power filtering. Specifically, three electrolytic capacitors smooth the 5 VDC supply for stable speed measurement. In addition, two tantalum capacitors provide high-frequency noise suppression for frequency converters. Moreover, the hold-up capacitors maintain trip logic during brief backplane power interruptions. Furthermore, the trip relays remain energized under normal operation and de-energize to trip. Therefore, this board provides fail-safe turbine protection without external battery backup.
Installation and Diagnostic Indicators
Seven LED indicators provide operational status at a glance on this board. First, a green Power LED lights when the backplane supply voltages are present. Second, three green Sensor OK LEDs illuminate when each speed sensor provides a valid signal. Third, two yellow Trip Active LEDs light when the module has activated an emergency trip. Finally, a red Fault LED indicates sensor failures, frequency errors, or comparator mismatches. Additionally, the board features six mounting holes for secure rack attachment. Thus, you can monitor trip protection status instantly without external test equipment.